OPC-UA Bridge

Connect the Methanol APC Environment to real plant DCS/SCADA systems via OPC Unified Architecture — the standard industrial communication protocol used by Honeywell Experion, ABB 800xA, Siemens PCS 7, Yokogawa CENTUM, and Emerson DeltaV.

Setup

pip install asyncua

No other configuration needed for server mode. For client mode, set:

export OPCUA_ENDPOINT=opc.tcp://plant-dcs.local:4840

Two Operating Modes

Server Mode — Shadow Deployment

Exposes the simulation as an OPC-UA server. Real HMI/SCADA systems connect to read simulated sensor values. Use this to:

  • Display AI suggestions alongside human operator actions
  • Validate agent behavior before switching to live control
  • Train operators on the AI's decision-making patterns
from methanol_apc_env.integrations import OPCUABridge

bridge = OPCUABridge(mode="server", endpoint="opc.tcp://0.0.0.0:4840")
await bridge.start()

# After each simulation step, publish state
await bridge.publish_state(reactor_state)

# Read setpoints written by external HMI operator
operator_setpoints = await bridge.read_setpoints()

await bridge.stop()

Client Mode — Live Plant Connection

Connects to a real plant's OPC-UA server. Reads live sensor data and writes agent actions to real actuators.

Safety

Client mode writes to real actuators. Only use after thorough validation in simulation mode and shadow mode.

bridge = OPCUABridge(mode="client", endpoint="opc.tcp://plant-dcs.local:4840")
await bridge.connect()

# Read live sensor data
readings = await bridge.read_plant_tags()
# {"temperature": 252.3, "pressure": 81.2, "catalyst_health": 0.93, ...}

# Write agent actions to DCS
await bridge.write_action({
    "feed_rate_h2": 5.2,
    "cooling_water_flow": 42.0,
    "compressor_power": 67.0,
})

await bridge.disconnect()

OPC-UA Tag Mapping

Tags follow the ISA-95 naming convention: Area.Unit.Instrument.Measurement

Process Values (PV) — Agent Reads These

OPC-UA Tag ReactorState Field Unit Description
METHANOL.REACTOR.TI001.PV temperature °C Reactor bulk temperature
METHANOL.REACTOR.PI001.PV pressure bar Reactor pressure
METHANOL.REACTOR.FI001.PV feed_rate_h2 mol/s Hydrogen feed rate
METHANOL.REACTOR.FI002.PV feed_rate_co mol/s CO feed rate
METHANOL.REACTOR.FI003.PV cooling_water_flow L/min Cooling water flow
METHANOL.REACTOR.TI002.PV cooling_water_temp °C Cooling water inlet temp
METHANOL.REACTOR.AI001.PV catalyst_health 0–1 Catalyst activity
METHANOL.REACTOR.FI004.PV reaction_rate mol/s Methanol formation rate
METHANOL.REACTOR.XI001.PV compressor_power kW Compressor power
METHANOL.REACTOR.FI005.PV methanol_produced kg Cumulative methanol
METHANOL.REACTOR.CI001.PV cumulative_profit $ Total profit
METHANOL.REACTOR.RI001.PV h2_co_ratio H₂/CO molar ratio
METHANOL.REACTOR.ZI001.PV emergency_shutdown bool Shutdown flag

Setpoints (SP) — Agent Writes These

OPC-UA Tag Action Field Unit
METHANOL.REACTOR.FI001.SP feed_rate_h2 mol/s
METHANOL.REACTOR.FI002.SP feed_rate_co mol/s
METHANOL.REACTOR.FI003.SP cooling_water_flow L/min
METHANOL.REACTOR.XI001.SP compressor_power kW
METHANOL.REACTOR.FV001.SP purge_valve_position %
METHANOL.REACTOR.FI006.SP recycle_ratio
METHANOL.REACTOR.TI003.SP feed_preheat_temp °C
METHANOL.REFORMER.FI001.SP reformer_fuel_gas mol/s
METHANOL.REFORMER.FI002.SP reformer_steam_flow mol/s
METHANOL.DISTILL.RI001.SP distillation_reflux
METHANOL.DISTILL.QI001.SP reboiler_duty kW
METHANOL.REACTOR.FV002.SP flare_valve %

Security

For production plant networks, enable OPC-UA security:

from methanol_apc_env.integrations.opcua_bridge import OPCUAConfig

config = OPCUAConfig(
    endpoint="opc.tcp://plant-dcs.local:4840",
    security_policy="Basic256Sha256",
    certificate_path="/path/to/client_cert.pem",
    private_key_path="/path/to/client_key.pem",
)
bridge = OPCUABridge(mode="client", config=config)

Deployment Path

  1. Simulation → Train agent on reactor_sim.py (no OPC-UA needed)
  2. Shadow mode → OPC-UA server exposes sim alongside real HMI
  3. Pilot → OPC-UA client reads real sensors, suggests actions (human approves)
  4. Production → OPC-UA client writes setpoints directly to DCS